Aaru Report for IBM DCAS-32160 S63A

SCSI characteristics:
Vendor: IBM
Product: DCAS-32160
Revision: S63A
Device is connected and supported.
Direct-access device
Device claims to comply with ANSI X3.131:1994 (SCSI-2)
Device does not claim to comply with any SCSI ECMA standard
Device does not claim to comply with any SCSI ISO/IEC standard
Device supports synchronous data transfer
Device supports linked commands
Device supports TCQ queue
Device does not support asymmetrical access
Device supports only ST clocking
Device supports MODE SENSE (6)

Device has 4226725 blocks of 512 bytes each
Device size: 2164083200 bytes, 2 Gb, 2.02 GiB
Medium type code: 00h
Density code: 00h
Long block size: 540 bytes
Device supports READ CAPACITY (10) command.
Device supports READ (6) command.
Device supports READ (10) command.
Device supports READ LONG (10) command.

SCSI mode sense pages:
Mode Contents
MODE page 01h SCSI Read-write error recovery page:
Parameters can be saved
Data not recovered within limits shall be transferred back before a CHECK CONDITION
Drive shall report recovered errors
Drive will repeat read operations 1 times
MODE page 02h SCSI Disconnect-Reconnect mode page:
Parameters can be saved
Data transfer disconnect control is not used
MODE page 03h SCSI Format device page:
Parameters can be saved
24564 tracks per zone to use in dividing the capacity for the purpose of allocating alternate sectors
0 sectors per zone that shall be reserved for defect handling
0 tracks per zone that shall be reserved for defect handling
0 tracks per LUN that shall be reserved for defect handling
171 physical sectors per track
512 Bytes per physical sector
Target-dependent interleave value is 1
29 sectors between last block of one track and first block of the next
52 sectors between last block of a cylinder and first block of the next one
Drive supports hard-sectoring format
Sector addressing is progressively incremented in one cylinder before going to the next
MODE page 04h SCSI Rigid disk drive geometry page:
3 heads
8188 cylinders
Write pre-compensation starts at cylinder 0
Write current reduction starts at cylinder 0
Heads park in cylinder 0
Spindle synchronization is disable or unsupported
MODE page 07h SCSI Verify error recovery page:
Parameters can be saved
Drive will repeat verify operations 1 times
MODE page 08h SCSI Caching mode page:
Parameters can be saved
Write-cache is enabled
Drive does not distinguish between cached read data
Drive does not distinguish between cached write data
Pre-fetch will be done for READ commands of 65535 blocks or less
A maximum of 65535 blocks will be pre-fetched
A maximum of 65535 blocks will be pre-fetched even if it is commanded to pre-fetch more
MODE page 0Ah SCSI Control mode page:
Parameters can be saved
The logical unit maintains one task set for all nexuses
Commands should be sent strictly ordered
If ACA is established, the task set commands shall resume after it is cleared, otherwise they shall terminate with CHECK CONDITION
LUN shall clear unit attention condition reported in the same nexus
On medium insertion, it shall be loaded for full access
MODE page 0Ch Unknown mode page
MODE page 1Ch SCSI Informational exceptions control page:
Parameters can be saved
Informational exceptions are enabled
No reporting of informational exception condition
MODE page 20h Unknown mode page
MODE page 21h Unknown mode page
MODE page 30h Unknown mode page
MODE page 32h Unknown mode page
MODE page 00h Unknown vendor mode page

SCSI extended vital product data pages:
EVPD Contents
EVPD page 01h 73H7716
EVPD page 03h S60BS63A
EVPD page 82h DCAS